Fix dropouts with Engin VOIP
Part 1: Your Siemens Speedstream 4200 router
Step 1: Login to your Siemens Speedstream 4200
- Start your web browser and type the private IP address of the router into the URL field and press ENTER.
- You will be prompted to enter username and password. By default, the username is admin and the password is admin or blank (ie do not fill in any password).
Step 2: Setup a port forwarding rule
- Go to Setup >> Port Forwarding;
- Select Protocol UDP;
- Enter UDP port: start port 5070 and end port 5071;
- Redirect to your voice IP address.
Part 2: Your Engin box
Step 1: Change the SIP ports for the LINE1 tab
- Go to Voice >> admin >> advanced;
- Go to LINE1;
- Go to SIP settings heading;
- Enter SIP port 5070;
- Enter SIP EXT port 5070.
Step 2: Change SIP ports for the PSTN tab
- Go to PSTN;
- Go to the SIP settings heading;
- Enter SIP port 5071;
- Enter SIP EXT port 5071.
Back to the Info Dump